******* Installation Instructions for Enigma Production Release 1.8 (04/21/2014) **********

                FOR

*** Enigma Link Decryptor Module ***
                  
NOTE: Please read these instructions carefully! Contact TI if you have any questions. Note that some filenames are very
      similar (*.pkg vs. *.pk), please ensure you load the correct file as required by these instructions.

NOTE: These instructions are only valid when upgrading from Enigma software 01.04 or later. If you have a SW version
      older than 01.04, please contact TI for assistance in upgrading your Enigma board.

NOTE: There are three release packages that must be used to upgrade your Enigma software:

         EnigmaFac_1_8_24.pkg (this is the factory software)
         EnigmaCSP_0_2_4.pkg (installed after EnigmaFac_1_8_24.pkg)
         EnigmaPro_1_8_24.pkg (this is the production software)

NOTE: You must use version v1.0(91) of the ICP/Enigma control program or newer. A version is provided in this release.

NOTE: If you are running the Production version of Enigma software, you must login before executing any commands.


=========== IF CURRENT ENIGMA SOFTWARE IS 1.0(13) or LATER, FOLLOW THESE STEPS =====================

1. Power up the Enigma. Launch the TI control program, enter the appropriate Enigma IP address in the "Ethernet 
   Configuration" window, and select the OEM Ethernet Port under the "Connection to Enigma" box of the 
   control program. Verify that you see "P1.0(13)" or "F1.0(13)" (or later) in the version box.

2. You may load EnigmaFac_1_8_24.pkg or EnigmaPro_1_8_24.pkg onto your Enigma. Do this by clicking on the "Browse" button,
   browsing to the location where the file is stored, selecting the file, and then clicking on "Load Release File to Slot".
   Wait for the completion message.

3. Install the loaded file. Do this by clicking the "Install Release from Slot" button. Wait for the completion 
   message. The control program will automatically re-connect to the Enigma. 

4. Verify that the software version now reads "F1.8(24)" or "P1.8(24)"

5. Load the EnigmaCSP_0_2_4.pkg. Do this by clicking on the "Browse" button, browsing to the location where the 
   file is stored, selecting the file, and then clicking on "Load Release File to Slot".  Wait for the completion message.

6. Install the loaded file. Do this by clicking the "Install Release from Slot" button. Wait for the completion 
   message. The control program will automatically re-connect to the Enigma. 

7. Verify that the "TI Login List" and "OEM Security Officer List" versions read "Enigma CSP 0.2(4)"

8. The Enigma is now upgraded and ready to use. Note that the production version of software requires a login 
   before commands be executed; the factory version does not. You can freely switch between the two depending 
   on your test or use requirements.



=========== IF CURRENT SOFTWARE IS 01.04 (OR LATER) BUT LESS THAN 1.0(13), FOLLOW THESE STEPS ======

1.  Power up the Enigma. Launch the TI control program, enter the appropriate Enigma IP address in the "Ethernet 
    Configuration" window, and select the OEM Ethernet Port under the "Connection to Enigma" box of the 
    control program. Verify that you see "P01.04" or "F01.04" (or later) in the version box.

2.  Load EnigmaFac_1_8_24.pkg by clicking on the "Browse" button, browsing to the location where the file is stored, 
    selecting the file, and then clicking on "Load Release File to Slot". Wait for the completion message.

3.  Install the loaded file. Do this by clicking the "Install Release from Slot" button. Wait for the completion 
    message. The control program will automatically re-connect to the Enigma. 

4.  Verify that the software version now reads "F1.8(24)"
    
5.  Load EnigmaCSP_0_2_4.pkg by clicking on the "Browse" button, browsing to the location where EnigmaCSP_0_2_4.pkg 
    is stored, selecting EnigmaCSP_0_2_4.pkg, and then clicking on "Load Release File to Slot". Wait for the 
    completion message.

6.  Install EnigmaCSP_0_2_4.pkg. Do this by clicking the "Install Release from Slot" button. Wait for the 
    completion message.

7.  Check the login list versions. Both should read "Enigma CSP 0.2(4)".

8.  If upgrading from an Enigma release of 0.3(9) or earlier, go to the Sys-Config page of the TI control program 
    and click the "Factory Reset >>" button.

9.  If upgrading from an Enigma release of 0.3(9) or earlier, go to the Sys-Status page of the TI control program
    and click the "Arm Tamper" button to arm the tampers on the Enigma. 

10. Load EnigmaPro_1_8_24.pkg by clicking on the "Browse" button, browsing to the location where the file is stored, 
    selecting the file, and then clicking on "Load Release File to Slot". Wait for the completion message.

11. Install the loaded file. Do this by clicking the "Install Release from Slot" button. Wait for the completion 
    message.  The control program will automatically re-connect to the Enigma. 

12. Login to the Enigma; verify that the software version now reads "P1.8(24)".

13. The Enigma is now upgraded and ready to use. Note that the production version of software requires a login 
    before commands be executed; the factory version does not. You can freely switch between the two depending 
    on your test or use requirements. You may also load any custom login lists into the Enigma at this time.