[DCC] --- Version changed from Ver5.1.8.3 to Ver5.1.8.6 01. Modify the update function logic on NC1201L series. --- Version changed from Ver5.1.8.0 to Ver5.1.8.3. 01. Supported to new ICP command for FMT FPGA Ver5.36(184)/4.52(3) that is used for DMD protection. --- Version changed from Ver5.1.6.0 to Ver5.1.8.0. 01. Fix the issue that DCC incorrectly sorts the Secure Log in Information viewer. 02. Fix the issue that it takes long time when changing the DCC connection to MMS from Projector. 03. Fix the issue that the DCC displaying becomes incorrectly when changing the DCC connection to MMS from Projector. 04. Fix the issue that DCC shows "??" as Lens Firmware Version with NC3200S. 05. Fix the issue that DCC can not backup with ICP configuration files having 2byte character file name. 06. Add the option to skip LUT-SCC file restoration when backup file restoration. --- Version changed from Ver5.1.7.0 to Ver5.1.8.0 for NC1700L 01. Delete the Diffuser Usage reset button 02. Add the Chiller Firmware Version and Chiller Serial number on [INFO]-[Status2] menu. 03. Add FAN MAP function. --- Version changed from Ver5.1.5.0 to Ver5.1.6.0 01. Fix the issue that "Information Viewer" shows logs incorrectly when sort display toggle. 02. Fix the issue that the icon on START - Light field gets collapse when Tab key pressed. 03. Delete [FMT Status] button from INFO. - Status menu.(NC1201L series) 04. Updated FAN and THERMISTOR MAP.(NC1201L series) 05. Support to indicate temperature sensor error with yellow in THERMISTOR MAP.(NC1201L series) 06. Support the "Sensor Calibration - Reset" function in UPDATE - Others.(NC1201L series) *If service person does not do sensor calibration within initial 100 hrs, this function enables to get and set sensor calibration value at factory shipping. 07. Add projector log extraction when projector backup. 08. Support to projector backup/restore function from terminal software. For more detail, see "NEC_projector_backup_restore_log_extraction_LDD16003_r1.pdf". 09. Fix the issue that sensor value in LIGHT menu is not updated correctly.(NC1201L series) --- Version changed from 5.1.1.0 to 5.1.5.0. 01. Combine "DCC for S2" and "DC Communicator for NC1201L series". 02. As for NC1100, in LIGHT menu, add to support to show calibrated sensor value. 03. As for NC1100, in Light Unit Status menu, add to support to show: calibrated and non-calibrated sensor value. current brightness vs target brightness. current color vs target color. 04. Changed the ReadCertTool from Ver4030 to Ver4070. - Supported option board NP-90MS02. ???- Added the supported USA model NP-NC1201L1-A. --- Version changed from Ver5.0.9.0 to Ver5.1.1.0 01. Add the Validity Setting function that is for rental business. --- Version changed from Ver5.0.8.0T to Ver5.0.9.0 01. Support Ballast FW Version, either of 0207/0207 or 0204/0204 for NC900C, in check version function. 02. Add feature to save secure log.(The button,"Save Secure Log(Cinema)", in DCC-INFO.-Status) The last 3 line in log file shows the number of all events, the number of all unread events, oldest unread event, and newest unread event. 03. Add the Lamp PS Type model in save information for NC1200C, NC2000C, NC3200S and NC3240S. 04. Support to show real Projector Tilt Status for NC1100L. For more detail, see the "RP4.214_Technical_Information_(NC1100).pdf". 05. Change the function name, "Phosphor Wheel - High/Low Speed" for NC1100L. For more detail, see the "RP4.214_Technical_Information_(NC1100).pdf". 06. Change the function name, "Slave/LD Board Maintenance" for NC1100L. For more detail, see the "RP4.214_Technical_Information_(NC1100).pdf". 07. Add feature to save secure log.(The button,"Save Secure Log(Cinema)", in DCC-INFO.-Status) for NC1100L The last 3 line in log file shows the number of all events, the number of all unread events, oldest unread event, and newest unread event. 08. Fix the string loss of “Diffuser” in Russian for NC1100L For more detail, see the "RP4.214_Technical_Information_(NC1100).pdf". --- Version changed from Ver5.0.8.0 to Ver5.0.8.0T 01. Add the Save Secure Log(Cinema) button on Info. page. The all secure log is stored and the lastest 3 line is checked result on the log. --- Version changed from Ver5.0.5.3 to Ver5.0.8.0 01. Support "Lamp Status" in GPO_1~4(SETUP-Setup-GPIO-GPIO Setting menu) *The change is only for NC2000. 02. Support "Direct Power On" feature.(SETUP-Setup-Direct Power On) Off: Projector goes to STBY when AC-ON. (Default) On: Turn the projector on automatically when AC-ON. *The change is only for NC2000. 03. Fix the bug where "Lamp Memory List" - "Lamp Mode" unexpectedly shows 0.0[A] when Entry/Delete/Test/Paste. *The change is only for NC900. 04. Implement Function to avoid DMD Brighter /Darker Pixels Issue *The change is only for NC3240. --- Version changed from Ver5.0.5.0 to Ver5.0.5.3 01. Fix the issue where all gray plane may show up for some time when starting to connect to projector. 02. Fix the issue where LENS menu layout may be corrupted depending on PC display DPI setting. 03. Fix the issue where "Maybe, projector is too busy" may occur. --- Version changed from Ver5.0.4.0 to Ver5.0.5.0 01. Fixed the bug where SETUP menu is available for user mode. --- Version changed from Ver5.0.3.0 to Ver5.0.4.0 01. Updated Digtial Certification Read tool ver 4.0.0.0. --- Version changed from Ver5.0.2.0 to Ver5.0.3.0 01. Added to check model type during TCP re-connection. --- Version changed from Ver5.0.0.0 to Ver5.0.2.0 01. Implemented PH800T feature and integrated the DCC code between NC900C and PH800T. 02. Fixed the issue where the ICP ESN shows in correctly on DCC log file when the last number is "FF". For example, if the ICP ESN is "01 02 03 04 05 06 07 FF", the log shows "??" as the ICP ESN. The ICP ESNs retrieved by ReadCertTool are no problem. 03. Changed the ReadCertTool from Ver3410 to Ver3420.(To support PH800T Series.) 04. Fixed the issue where the message, "Maybe, projector is too busy.", shows up when Enigma update is tried through DCC HTTP connection mode. 05. Fixed the issue where internal test patterns through DCC - SETUP - Color Setting - [Red]/[Green]/[Blue]/[White]/[Black] can not be activated when DCC language is either of Chinese, Russian, Spanish, or Portuguess. --- Version changed from Ver4.2.0.0 to Ver5.0.0.0 01. Full-Auto update is modified to - Support to download CPU DATA and Built-in DCC independently on Full-Auto update. - keep Enigma Security Log.(In other words, Enigma Security Log will not be cleared by Full-Auto update.) 02. The layout of [Read cert Tool] button and Signature Test - [Enable]/[Disable] buton are changed. For more detail, "RP4.201 Technical Information_r2.pdf". 03. Fix the issue where the timestamps in maintenance log are not updated. 04. Change the default setting of "Include Usage Reset Log" to "check on". 05. Disable the function, DCC-UPDATE-Debug Option Setting-ICP Command Input. Because it can not be used due to ICP S/W limitation. 06. Fixed the bug where new file name does not show on the bottom of DCC when the current screen setting can be changed temporarily from DCC-MAIN-Test-Advanced-SCREEN File Setting menu. ---- Release Note for DCC Version 4.2.0.0 ---- (2012.12.14) --- Version changed from Ver4.1.3.0 to Ver4.2.0.0 1) Projector Time(Timezone) can be adjusted in minutes. It affects on NC900C only, not affects on others than NC900C. 2) From this version, DCC is released as common. It supports all NEC series2 cinema projectors. ---- Release Note for DCC Version 4.0.2.0 ---- (2012.07.20) - Changed DCC from Ver4.0.1.0 to Ver4.0.2.0 1) Add MMS setting menu to SETUP menu. (Only factory mode) ---- Release Note for DCC Version 4.0.1.0 ---- (2012.06.28) - Changed DCC from Ver4.0.0.0 to Ver4.0.1.0 1) Supported to install ICP4.0(425) If you are upgrading an ICP from Prod4.0 or earlier to Prod 4.0(425), you must use DCC Version 4.0.1.0 or later. 2) Add Quad input mode check box in TITLE-Advanced window Quad input mode is used when only IMB input with NC3240S 3) Add the FMT Reset Recovery setting in UPDATE-Others window [Enable] Automatic recovery when Satellite Link Error or Report Reset occurred during showing. FMT Recovery takes about up to 75sec. Display image is confused during FMT Recovery [Disable] Not working FMT recovery when Satellite Link Error or Report Reset occurred during showing. 4) Fix the bug, can not install to PC when install the DCC for the first time. ---- Release Note for DCC Version 4.0.0.0 ---- (2012.05.14) - Changed DCC from Ver3.3.1.0 to Ver4.0.0.0 1) Supported to install ICP3.x. If you are upgrading an ICP from Prod3.2 or earlier to Prod 4.0 or later, you must use DCC Version 4.0.0.0 or later. 2) Changed the name from "After Time" to "Remaining Time" in sleep timer window. 3) Supported to display two line menu mode Check the "Display two line" setting in Option Tab when use two line menu. 4) Supported to launch the Read Cert Tool from DCC-UPDATE-Other button. Read Cert Tool is installed to PC when install the DCC Version 4.0.0.0 ---- Release Note for DCC Version 3.3.1.0 ---- (2012.02.24) - Changed DCC from Ver3.3.0.0 to Ver3.3.1.0 1) Support S/N maintenance function for recovery of the projector S/N. (For more detail, see the technical document.) (UPDATE - Others - SN Maintenance) 2) Add information in Save Info. - ICP Status - Error Status - Title List - Gateway - Maintenance Log(Auto install log is shown in the field.) 3) Add to show the detail information of "DLP Ack Fail" error in Information Viewer. (For more detail, see the technical document.) (UPDATE - Information Viewer) 4) Delete MMS setting menu from SETUP menu. Note: You should setup only option slot setting for MM3000B. 5) Support electric convergence setting on ICP Prod3.2 or higher. 6) Expand bulb entry list from 32 to 80. Note: List 1..64 are for NEC certified lamps. 7) Change the button name from "Save" to "Save As..." in below menu. ?- SETUP - Color Setting ?- TITLE - PCF Setting ?- TITLE - SCREEN Setting ?- TITLE - 3D Controls 8) Support to setup power-off time in sleep timer. (For more detail, see the technical document.) (SETUP - Sleep Timer - Setting) 9) Fix the bug where "Restore function" looks work fine while projector in STBY. (UPDATE - Restore from PC - Restore) 10) Add lamp strike count information. (INFO. - Log - Usage Reset Log) 11) Add Debug Log Option function.(For more detail, see the technical document.) (UPDATE - Debug Option - Setting) - Changed DCC from Ver3.2.1.0 to Ver3.3.0.0 1) Support to Japanese DCC. - Changed DCC from Ver3.2.0.0 to Ver3.2.1.0 1) Support to enable/disable Datapath Signature Test at startup. Current status is written in save information log Add the log into Operation log when change the enable/disable status 2) Add the semiauto update function that is used when replace the CPU or ICP board. If you don't have backup file(All), projector will become to factory default after semiauto update. - Changed DCC from Ver3.1.0.0 to Ver3.2.0.0 1) Add the input format for DVI 3D. - 3D 8bit - 3D Twin 8bit 2) Add the GPIO command for IMB. 3) Add the SIB EDID update function. 4) Expand Preset Buttons form 8 to 16 5) Add SAT icon for type icon 6) Add information in Save info - ICP indicate disk space available - Encrypted service password - SIB EDID Version9) Add the customize PJ douser auto control mode 7) Support to the service password customize each projector like a “Advanced user” and “installation”. Encryption service password is indicated in save info log . 8) Support to Russian DCC 9) Change the update process -Full Auto Update 10) Lens Mount Initialize button is removed from DCC with lower than service. 11) Support to show "Lens Memory Store Status" 12) Support to "Filter Usage Clear" -Body Filter -Lamp Filter 13) Support to "Fan Usage Clear" -AC On Fan -Power On Fan -Lamp Fan 14) 9) Support to the PJ douser control mode -Open(Power On) -Lamp On -Title Select 15) Add the Backup to PC-All button it include "All Cinema Files" and "Set Setting" - Changed DCC from Ver3.0.1.0 to Ver3.1.0.0 1) Add a function into DCC to view and select LUT-SCC files in the projector. So select a file so that you can get good looking image. The file will be default activated for a projector from next boot up. This function will be used when update to ICP Prod3.1 2) Backup/Restore/Check Version/Auto Install supported LUT-SCC files. 3) Backup/Restore supported CSC and TCGD files. 4) Add information in Save Info - Attached ICP HW revision - SIB BIOS version - Current LUT-SCC file name 5) Widen error window 6) Fix the bug, title information is unmatched between drop down list and another in DCC - TITLE menu. title. 7) Support to show attached ICP HW revision on DCC-INFO-Status. 8) Add the IMB reset for emergency use. Do not use it fot GDC IMB until NECDSJ makes an announcement because GDC server can not play a show after only IMB reset at this moment. 9) Support to the setting 2:2 frame rate ratio in 3D setting file when ICP Version is Prod3.1 10) Support to show attached SIB BIOS version on DCC-INFO-SIB/IMB. 11) Support to entry the bulb cert code made by wrong number of year. 12) Add the SIB reset when update only SIB OS in All update - Changed DCC from Ver3.0.0.0 to Ver3.0.1.0 1) Added vTrapStatus filtering.(Affected: LAN\SNMP\Trap Filtering\vTrapStatus) You can select either of or . Note: This function does not work fully on PJ emulator. 2) Supported ETG-RN(IO-data router) firmware update in all update procedure. 3) Modified that setting item with tick is showing w/o highlit when open the next dialogs. LAN\SNMP\Set Critical Error List LAN\SNMP\vTrapProtect SETUP\Setup\GPIO-Setting\Error Status List Setup - Changed DCC from Ver2.4.1.1 to Ver3.0.0.0 1) Added IMB icon in title bar.(Affected: MAIN\Preset Button, MAIN\Title) 2) Supported switching of projector behavior when "Lamp Unlit".(Affected: SETUP\Setup\Unlit Mode) 3) Supported "NewRouterSetup".(Affected: SETUP\Installation\New Router Setup) 4) Supported SNMP Trap2/3 filterling.(Affected: LAN\SNMP\Set Trap Output Filtering) 5) Changed initialization of TLS communication with Enigma/IMB. 6) Added One-Click Update.(Affected: UPDATE\Check Version\Auto\All Update 7) Supported switching "GPO Error Status Bit" behavior.(Affected: SETUP\Setup\GPIO\Error Status List Setup) 8) Fixed the bug where files which timestamp ranges from 1970 to 1979.(Affected: UPDATE\Backup to PC) 9) Disabled IMB Reset button.(Affected: SETUP\Option Slot\Reset IMB) 10) Supported Lamp Strike Log viewer.(Affected: UPDATE\Maintenance\Information Viewer\Lamp Strike Log) 11) Changed timeout in Enigma/IMB Re-Marriage from 7 to 14 seconds.(Affected: SETUP\Installation\Enigma maintenance\Re-Marriage, SETUP\Installation\IMB Maintenance\Re-Marriage) 12) Added error message in detail will be shown when Enigma/IMB Re-Marriage is failed. - Changed DCC from Ver2.4.1.0 to Ver2.4.1.1 1) Removed Mirror Park(MAIN - TITLE) function.(Affected in connecting to NC3240) 2) Added SIB power-cycle in last stage of SIB remote update. 3) Supported NC-80DS01 in SETUP - Option Slot - Option Slot Setting. * To activate GUI, NEC CPU firmware supporting NC-80DS01 should be installed into the projector. At this time, only NC3240 CPU firmware support NC-80DS01. 4) Fixed the bug(fragment issue). The problem could be easy to appear when a mount of data is transferred to DCC.(For example, large log file.) - Changed DCC from Ver2.4.0.0 to Ver2.4.1.0 1) Supported NC3240S-A. 2) Supported next generation router unit(7N970107 "ROUTER BR-CP1400N") as well in check version. This router unit is used in NC3240S-A, then will be applied in NC3200/2000/1200 as running change. 3) Fixed the bug where Alert Mail setting is showing OFF even if the practical value is ON. 4) Invalid bulbs are shown with gray color in bulb list. 5) Fixed the bug where [_] (minimize button) and [X](exit button) are shown at a wrong location when PC display resolution is smaller than 800x640. 6) DCC shows the warning message, "YOU MUST NOT DOWNGRADE AN ICP WITH THE 16MB FLASH TO AN ICP PRODUCTION RELEASE LOWER THAN PRODUCTION 1.4. IF YOU DO, YOU WILL MAKE THE BOARD NON-FUNCTIONAL." when you do. Fixed the bug where DCC would be crashy when this message is closed. 7) Supported to install ICP3.x. If you are upgrading an ICP from Prod2.x or earlier to Prod 3.0 or later, you must use DCC Version 2.4.1.0 or later. 8) Supported to show/log IMB status. To show/log IMB status, you should update NEC CPU firmware to control the IMB.(Currently not released yet.) 9) Supported IMB re-marriage button.(SETUP - Installation) Do not use the button until the way to use it will be released. 10) Prolonged the timeout during the reading ICP log, installing ICP, and installing Secure Data. ---- Release Note for DCC Version 2.4.0.0 ---- (2010.09.27) - Changed DCC from Ver2.3.0.0 to Ver2.4.0.0 1) Added [Server Information] button to view the status of "Timeline", "Subtitle", and "Metadata". 2) Disabled the functions in the following menus during Metadata is enable. (The same as Series1) MAIN - Preset Button MAIN - Title MAIN - Test TITLE SETUP - Setup - Factory Default SETUP - Color Setting 3) Added the ICP status window during ICP firmware update procedure.(Only valid Special Mode Boot) ---- Release Note for DCC Version 2.3.0.0 ---- (2010.09.07) - Changed DCC from Ver2.2.2.0 to Ver2.3.0.0 1) Added "Router Firmware" information into the log file through DCC. 2) Supported "check version" of the Router Firmware. 3) Changed the size of Check Version dialog. 4) Changed "Check Version" to accept both current(*1) and newer(*2) version of FMT Configuration Firmware on ICP. (*1) 1.00(24) (*2) 1.00(25) [Supplement] So far, there are two versions of FMT Configuration Firmware on ICP board. From around October, the ICPs for production and service part will be replaced to the new one with 16MB flash. The new one is supporting both 2K and 4K projector. Note that FMT Configuration Firmware 1.00(25) should be installed into the new board to boot the new 16MB flash. Each of 1.00(24) and 1.00(25) is acceptable for the current board. The behavior of 1.00(25) is the same as 1.00(24) on the current ICP board. The difference between 1.00(24) and 1.00(25) is only flash boot sequence. So they can work on the current ICP with 8MB. In addition, the FMT Configuration Firmware can be pre-installed on board production. We can not install it into the board through DCC/ICP&Enigma Control Program. - Changed DCC from Ver2.1.1.0 to Ver2.2.2.0 1) Added new information below into the log file through DCC. ICP Input Timing SMPTE Error Counter Enigma Status(FPGA Decryption Status) 2) Supported "check version" of Router Cfg data and Lens firmware. 3) Re-selection of the current bulb is allowed. 4) "Reserved" is showing for empty bulbs in the first 16 bulb locations. (the first 16 lamp locations are not editable to change settings (only warranty time)) 5) Supported the settings of "Heartbeat stop in cooling and standby" in the GPIO Setting dialog. 6) Changed the layout of GPIO Setting dialog. Note1: When GPI/GPO setting duplicate assignments, they are showing with red. Note2: Idle status becomes static.(All "Lo") 7) Added SIB Error Counter(SMPTE Error Counter) clear button. INFO. - SIB - Current Status 8) Fixed the bug where a MM3000B title is backed up with MM Setting == Not Use. 9) Fixed the bug where wrong temperature value was logged into the log file. 10) Fixed the bug where wrong input format is showing in SDI status. INFO. - SIB - Current Status Before bug fix After bug fix SMPTE 296M 720p 60Hz >> SMPTE 274M 1080sF 24Hz SMPTE 274M 1080sF 24Hz >> SMPTE 296M 720p 60Hz ---- Release Note for DCC Version 2.1.1.0 ---- (2010.07.06) - Changed DCC from Ver2.0.1.0 to Ver2.1.1.0 1) Changed that DCC does not downgrade an ICP board with 16MB flash(*1) to an ICP firmware lower than Prod1.4. (Affected: UPDATE - ICP Update - ICP firmware) (*1) It is supporting 4K and will be released in the near future. 2) Added displaying new information of ICP bd, FMT bd, and DMD type. (Affected: INFO. - Status - Cinema Board, INFO. - Status - Save Information) - ICP bd - ICP(8M): An ICP board type with 8M flash is attaching to the projector. ICP(16M) An ICP board type with 16M flash is attaching to the projector. *An ICP(8M) is current board. It supports 2K only. An ICP(16M) is released in near future. It supports both 2K and 4K. - Satellite bd - 2xLVDS: "LVDS" type satellite board is attaching to the projector. 2K DDR: "2K DDR" type satellite board is attaching to the projector. 4K DDR: "4K DDR" type satellite board is attaching to the projector. - DMD - 0.98" DC2K(2xLVDS): 0.98" DMD is attaching to the projector. 1.2" DC2K(DDR): 1.25" DMD is attaching to the projector. 1.38" DC2K(DDR): 1.38" DMD is attaching to the projector. ---- Release Note for DCC Version 2.0.1.0 ---- (2010.05.31) - Changed DCC from Ver2.0.0.0 to Ver2.0.1.0 1) Supported to show in INFO. - Status - ICP Status. 2) Fixed the bug where warranty editing of "XBO 4000W/HPN" and "XBO 6500W/HPN" leads to fail. 3) Fixed the bug where caused communication error when no SIB is selected as default option board. 4) Removed Enigma information from result when no SIB is selected as default option board. 5) Removed Enigma information from when no SIB is selected as default option board. ---- Release Note for DCC Version 2.0.0.0 ---- (2010.05.18) - Changed DCC from Ver1.0.0.5 to Ver2.0.0.0 1) Increased timeout for the communicate with Enigma board. 2) Fixed the bug where the blank is showing as "Use Line Interleave(1st line=Left 2nd line=Right" in 3D Control - L/R Input Reference. * Setting value is reflected correctly. 3) Changed the layout of UPDATE menu. 4) Supported ICP/Enigma/Secure Data(ICP loginlist/Enigma loginlist/OEM Security Officer List) update. For more detail, please see the document, "Projector update.pdf". 5) Supported to extract Secure Log from Enigma board. button(which is placed in INFO. - Log menu) is functional. Secure Log is loaded into log file. 6) Upgraded Check Version function. For more detail, please see the document, "Projector update.pdf". 7) Added button which is placed into SETUP - Installation menu. The button should be used to remove the "(481) Security Enclosure Not Armed". The button is available when Service login level or higher. (*)Normaly, "(481) Security Enclosure Not Armed" will not occurred in the field. When it will occur unexpectedly in the field, remove this error with button. 8) Added indicator if new configuration(static, not user setting) is loaded into router. When new configuration is loaded into router unit, "*" is showing beside IP address information in INFO. - Status. +----------------+ | IP Address | || | | |(192.168.10.10 )| +----------------+ "*" is showing beside IP address information in log file. **** PJ Version **** IP Address* 192.168.10.10 / 255.255.255.0 9) Supported to entry bulbs certified by NEC. For more detail, please see the document, "New bulb entry.pdf". 10) Supported to show subtitle function status. *NOT mean supporting subtitle function. 11) Upgraded Usage Reset Log. For more detail, please see the document, "New bulb entry.pdf". 12) "??" is showing as ICP version in log file when no responses from ICP board during power-on mode. Change from to **** ICP Version **** >> **** ICP Version **** Serial Number ?? Serial Number ?? ICP SERIES-1 ICP ?? Satellite Red DDR Satellite Red ?? Satellite Green DDR Satellite Green ?? Satellite Blue DDR Satellite Blue ?? DMD Unknown DMD ?? OS 0.00 (0) OS ?? Kernel 0.00 (0) Kernel ?? RAMDISK 0.00 (0) RAMDISK ?? ICP Boot Software 0.00 (0) ICP Boot Software ?? ICP Boot Firmware 0.00 (0) ICP Boot Firmware ?? ICP Main Software 0.00 (0) ICP Main Software ?? ICP Main Firmware 0.00 (0) ICP Main Firmware ?? ICP Configuration Firmware 0.00 (0) ICP Configuration Firmware ?? Secure Processor Software 0.00 (0) Secure Processor Software ?? FMT Boot Software 0.00 (0) FMT Boot Software ?? FMT Boot Firmware 0.00 (0) FMT Boot Firmware ?? FMT Main Software 0.00 (0) FMT Main Software ?? FMT Main Firmware 0.00 (0) FMT Main Firmware ?? FMT Satellite Firmware 0.00 (0) FMT Satellite Firmware ?? FMT Configuration Firmware 0.00 (0) FMT Configuration Firmware ?? FMT Sequence File 0.00 (0) FMT Sequence File ?? FMT DMD File 0.00 (0) FMT DMD File ?? ICP Login List ?? ICP Login List ?? 13) Fixed the bug where caused communication error when no SIB is selected as default option board. ---- Release Note for DCCS2 Version 1.0.0.5 ---- (2010.03.29) - Changed DCCS2 from Ver1.0.0.4 to Ver1.0.0.5 (1)Added router MAC address to "Save Infomation log". (2)Supported MAC Address from INFO - Status. (3)Supported 4:2:2/12bit format IMB title. ---- Release Note for DCCS2 Version 1.0.0.4 ---- (2010.03.04) - Changed DCCS2 from Ver1.0.0.0 to Ver1.0.0.4 (1) Deleted Douser Count Information from LAMP - Information.(When connected to NC3200S) (2) Deleted Douser Count Clear from LAMP - Setup.(When connected to NC3200S) (3) Upgraded the speed of browsing of information viewer. (4) Fixed the bug where file open error occurs in "UPDATE - Check Version" when *.ncversion file' attribute is read only. (5) Corrected mis-spelling: "Lamp House" in the log file. (6) Supported SIB OS update.